Blog Post — Blogs

Best Ex Equipment: Types, Standards & Uses (2026 Guide)

● July 16, 2025
ATEX Zone 1/21 IP68

Featured ATEX Products

Best Ex Equipment: Types, Standards & Uses (2026 Guide)

“Ex equipment” is equipment certified for use in an explosive atmosphere, where the “Ex” marking states which protection concept it uses and which conditions it is approved for. The main concepts are flameproof (Ex d), increased safety (Ex e), intrinsic safety (Ex i), pressurisation (Ex p) and encapsulation (Ex m), and each prevents ignition by a different mechanism. Which one you need depends on the zone, the gas group and the temperature class of the area. Equipment is certified under ATEX in the European Union, IECEx internationally, or the NEC and CEC Class and Division system in North America.

Discover the best Ex equipment for hazardous areas in this 2026 guide. Learn key types, safety standards (ATEX), and real-world uses for industrial protection.

What Are Ex Equipment? Complete Safety Guide 2025

Ex Equipment are specialized devices engineered for use in potentially explosive atmospheres. These include electrical or mechanical systems that are designed to operate safely in areas where flammable gases, vapors, or dust are present. Commonly used in industries like oil & gas, mining, chemicals, and pharmaceuticals, Ex Equipment reduce the risk of explosion by adhering to strict international safety standards.

In this article, we’ll explore the full scope of Ex Equipment— including their types, certifications, zone classifications, and best practices for usage.

ex equipment

What Does “Ex” Actually Mean?

The prefix “Ex” refers to explosion protection. Ex Equipment are constructed to eliminate or control sources of ignition in hazardous environments. These devices are governed by regulatory frameworks like ATEX (EU) and ATEX (International), ensuring they meet rigorous safety and performance standards.

Why Are Ex Equipment Needed in Industry?

Hazardous environments often contain:

  • Flammable gases (e.g., methane, propane)

  • Vapors from volatile liquids (e.g., alcohols, fuels)

  • Combustible dust (e.g., sugar, flour, coal)

In such areas, even a small electrical spark or temperature increase can result in devastating explosions. Using Ex Equipment ensures:

  • Protection of personnel

  • Prevention of asset damage

  • Compliance with local and global safety regulations

  • Operational continuity in critical industrial zones

What Are the Main Types of Ex Equipment?

Ex equipment is grouped by protection concept rather than by product type. Flameproof (Ex d) contains an internal explosion, increased safety (Ex e) prevents arcs and hot surfaces arising at all, intrinsic safety (Ex i) limits energy below the ignition threshold, pressurisation (Ex p) keeps the atmosphere out with clean air or inert gas, and encapsulation (Ex m) seals live parts in compound.

Different protection techniques are used in manufacturing Ex Equipments. Here’s a breakdown of the most common types:

1. Flameproof (Ex d)

This method encloses the device in a strong housing that can withstand an internal explosion and prevent it from spreading to the surrounding atmosphere.

Use Case: Motors, switches in petrochemical plants

2. Increased Safety (Ex e)

These devices are designed with added security to avoid arcs, sparks, and excessive temperatures.

Use Case: Junction boxes, terminal blocks in Zone 1 areas

3. Intrinsically Safe (Ex i)

Electrical circuits are designed so they cannot release enough energy to ignite an explosive atmosphere — even in fault conditions.

Use Case: Instrumentation and control systems in Zone 0

4. Pressurized Equipment (Ex p)

A protective gas (like nitrogen or air) is maintained at pressure inside the enclosure to prevent the entry of flammable substances.

Use Case: Analyzer cabinets in refineries

5. Encapsulation (Ex m)

Components are sealed with compound or resin to isolate them from the environment.

Use Case: Electronic components, transformers

Which Certifications Apply to Ex Equipment?

Ex Equipments must be certified according to international standards before deployment. Key certifications include:

1. ATEX Certification (Europe)

Mandated by EU Directive 2014/34/EU, it governs equipment used in explosive atmospheres within the European Economic Area.

2. IECEx certification (International)

The ATEX scheme provides a standardized global approach, making equipment acceptable in multiple countries.

3. NEC & CEC (USA & Canada)

The National Electrical Code (NEC) and Canadian Electrical Code (CEC) classify hazardous locations and equipment requirements for North America.

These certifications validate that the Ex Equipments are safe, tested, and approved for specific zone applications.

How Are Hazardous Areas Classified into Zones?

Under the IEC and ATEX system, gas atmospheres are Zone 0, 1 or 2 and dust atmospheres are Zone 20, 21 or 22, according to how likely an explosive atmosphere is to be present. Zone 0 and Zone 20 mean it is present continuously or for long periods; Zone 2 and Zone 22 mean it is unlikely and would be short-lived.

Hazardous areas are classified based on the frequency and duration of explosive atmospheres. Ex Equipments must match the specific zone they’re used in:

Zone Description
Zone 0 Explosive atmosphere present continuously or for long periods
Zone 1 Likely presence during normal operation
Zone 2 Not likely to occur during normal operation, or only for short durations

Ex Equipments must be selected carefully according to these classifications to ensure both safety and compliance.

Which Industries Use Ex Equipment?

Various sectors rely heavily on Ex Equipment of operate safely in harsh environments:

  • Oil & Gas Industry: Drilling rigs, refineries, pipelines

  • Chemical Plants: Where flammable liquids are stored or processed

  • Mining Operations: Where gases and coal dust are prevalent

  • Pharmaceutical Facilities: Cleanroom environments with volatile solvents

  • Food Processing Units: Dust-producing environments (e.g., flour, sugar)

Each of these industries requires Ex Equipments certified for specific hazards and environmental conditions.

What Components Make Up an Ex System?

  • Explosion-proof lighting fixtures

  • Flameproof motors and starters

  • Gas detectors and analyzers

  • Intrinsically safe control panels

  • Explosion-proof cameras

  • Hazardous area communication devices

At Infinity-Ex, you can find all major types of Ex Apparatus along with technical support for selection and installation.

How Is Ex Equipment Inspected and Maintained?

Routine Checks Should Include:

  • Physical condition (no cracks or corrosion)

  • Gaskets, seals, and enclosures

  • Proper cable entries and terminations

  • Grounding and bonding

  • Certification tag readability

Documentation should be maintained to record compliance and inspection intervals. Any damaged or uncertified equipment must be replaced immediately to ensure area safety.

How Do You Choose the Right Ex Apparatus?

  • Confirm the zone classification (Zone 0, 1, or 2)

  • Identify the type of hazard (gas, vapor, dust)

  • Check temperature class and IP rating

  • Ensure correct certification (ATEX, UL)

  • Assess environmental factors like humidity, corrosion, and temperature

Always consult a certified supplier or engineer before purchasing.

this devices are essential tools for ensuring safe operations in explosive and hazardous environments. Their design, certification, and deployment must meet global standards to mitigate the risk of fire and explosion. By understanding the types, applications, and certification standards of Ex Devices industries can operate more safely and efficiently.

Industrial Applications & Real-World Use Cases

In hazardous industrial environments such as oil refineries, petrochemical plants, offshore platforms, and mining operations, reliable communication is a critical safety requirement. Workers in Zone 1 and Zone 21 classified areas face constant exposure to flammable gases, vapors, and combustible dust. Any electronic device used must be intrinsically safe to prevent ignition.

Oil & Gas Operations

Field engineers on drilling rigs, well pads, and production platforms rely on ATEX certified devices for work order management, real-time communication with control rooms, digital permit-to-work systems, and photographic documentation. Our devices are deployed across ADNOC, Saudi Aramco, KOC, KNPC, ONGC, Petrobras, and Shell facilities worldwide.

Refinery & Petrochemical Safety

Process safety management requires continuous communication between operators, maintenance technicians, and HSE personnel. ATEX phones enable instant push-to-talk during turnarounds, emergency responses, and inspection rounds. Explosion-proof tablets allow viewing P&IDs and digital checklists in the field.

Offshore Platform Operations

Offshore environments present salt spray corrosion, extreme weather, and limited charging infrastructure. Our IP68-rated devices withstand these conditions while maintaining Zone 1 certification for crane coordination, emergency mustering, and helicopter manifesting.

Safety Compliance Standards

  • ATEX Directive 2014/34/EU — European explosive atmospheres standard
  • Ex ia IIC T4 Gb — Zone 1 intrinsic safety for gas groups
  • Ex ia IIIC T135°C Db — Zone 21 dust protection
  • IP68 — Dust and water protection
  • MIL-STD-810H — Military-grade durability

Browse Products → | Request Quote → | Certifications →

Related ATEX Products & Resources

Explore our range of ATEX-certified devices for hazardous areas:

Selecting the Right Device for Your Operation

Choosing the correct explosion-proof device depends on your specific operational requirements, environmental conditions, and workflow needs. Here are the key factors to consider when evaluating intrinsically safe communication equipment for your facility:

For Field Operators and Technicians

Personnel performing daily rounds, equipment inspections, and maintenance tasks benefit from compact phones with long battery life and rugged construction. The EX72 Plus delivers excellent balance between size, durability, and Zone 1 certified functionality for hands-on field work.

For Engineers and Supervisors

Professionals who need to reference drawings, access CMMS systems, review data trends, and manage digital permits require larger displays and more processing power. The EX 101 Ultra and INFINITY EX 100 PRO provide the performance needed for these demanding tasks while maintaining full ATEX certification.

For Tablet-Based Workflows

Operations transitioning to digital permit-to-work, electronic logbooks, or tablet-based inspection systems need larger screen formats. The TL110 5G Tablet provides a desktop-class experience in a Zone 1 rated package, ideal for control room extensions, field engineering, and supervisor walkdowns.

Key Selection Criteria

  • Zone classification of your operating environment (Zone 1 gas and/or Zone 21 dust)
  • Temperature range at your facility (our devices operate from minus 20 to plus 60 degrees Celsius)
  • Battery duration needed for your shift length (8, 12, or 16 hour shifts)
  • Application requirements such as SAP, push-to-talk, camera quality, or GPS accuracy
  • Network compatibility with your facility communications infrastructure

Contact our team for a personalized device recommendation based on your specific operational requirements.

Frequently Asked Questions

What does Ex stand for on equipment?

Ex marks equipment certified for use in an explosive atmosphere. The letters that follow identify the protection concept, such as Ex d for flameproof or Ex ia for intrinsically safe.

What is the difference between Ex d and Ex i?

Ex d (flameproof) allows ignition to occur inside the enclosure and contains it so the flame cannot reach the outside atmosphere. Ex i (intrinsic safety) prevents ignition happening at all by limiting the available electrical and thermal energy, which is why it is used for portable and battery-powered devices.

Does an ATEX marking work everywhere in the world?

No. ATEX is the mandatory scheme within the European Union, IECEx is the international scheme, and North America uses NEC and CEC Class and Division approvals. Equipment used across regions is often certified under more than one.

Can Ex equipment be repaired on site?

Only within strict limits. Repairs that affect the protection concept — such as an Ex d flamepath or an Ex i circuit — must follow the relevant standard and are normally done by an approved repairer, because an incorrect repair voids the certification.

Need a Custom Quote?

Our team of ATEX specialists is ready to help you find the right solution for your hazardous area operations.

Chat with us